EasyManuals Logo

Datalogic Gryphon 2D Series Product Reference Guide

Datalogic Gryphon 2D Series
354 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #257 background imageLoading...
Page #257 background image
Motion Features Enter/Exit Programming Mode
Product Reference Guide 247
Motionless Timeout
Specifies the waiting time in 100 millisecond ticks to assume that the reader is
in a motionless condition. The selectable range is 500 msec to 25.5 Seconds.
When no motion event is detected for a period of time longer than this timeout,
the software assumes the reader is in a motionless condition. This normally
results in returning the scanner to Stand Mode. This option relates to such fea-
tures as Aimer On and Stand Mode Object Sense scanning with respect to
mo
tion.
Select Motionless Timeout Setting
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at
l
eft followed by three digits from the Alphanumeric
characters in
Appendix D, Keypad
representing
your desired character(s). End by scanning the ENTER/
E
XIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and
not s
ave the entry string. You can then start again at the
beginning.
CANCEL
DEFAULT
020 = Motionless Timeout = 2 seconds

Table of Contents

Other manuals for Datalogic Gryphon 2D Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Gryphon 2D Series and is the answer not in the manual?

Datalogic Gryphon 2D Series Specifications

General IconGeneral
BrandDatalogic
ModelGryphon 2D Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals