1D Symbologies Enter/Exit Programming Mode
Product Reference Guide 183
Codabar Set Length 2
This feature specifies one of the bar code lengths for Codabar Length Control
on page 182
. Length 2 is the maximum label length if in Variable Length on
page 182
Mode, or the second fi
xed length if in
Fixed Length on page 182
Mode. The length includes the bar code’s sta
rt, stop, check and data charac-
ters. The length must include at least one data character.
The length can be set from 3 to 50 characters. A setting of 00 specifies to
ig
nore this length (only one fixed length). See
"Set Length 2" on
page 303 for
more detailed progr
amming instructions.
Select Codabar Length 2 Setting
To configure this feature, scan the ENTER/EXIT bar code
above, then the bar code at left followed by digits from
the Alphanumeric characters in
Appendix D, Key-
pad
representing your desired character(s). End by
scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and
not save
the entry string. You can then start again at the
beginning.
CANCEL
DEFAULT
50 = Length 2 is 50 Characters
$CCBL2
~

Table of Contents

Other manuals for Datalogic Gryphon 2D Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Gryphon 2D Series and is the answer not in the manual?

Datalogic Gryphon 2D Series Specifications

General IconGeneral
BrandDatalogic
ModelGryphon 2D Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals