1D Symbologies Enter/Exit Programming Mode
Product Reference Guide 205
MSI Set Length 2
This feature specifies one of the bar code lengths for MSI Length Control on
page 203
. Length 2 is the maximum label length if in Variable Length on page
203
Mode, or the second fixed length if in Fixed Length on page 203 Mode.
Length includes the bar code’s check, data, an
d full-ASCII shift characters. The
length does not include start/stop characters.
The length can be set from 1 to 50 characte
rs. A setting of 0 specifies to ignore
this length (only one fixed length). See
"Set Length 2" on
page 303 for more
detailed programming instructions.
$
Select MSI Length 2 Setting
To configure this feature, scan the ENTER/EXIT bar code
above, then the bar code at left followed by digits from
the Alphanumeric characters in
Appendix D, Key-
pad
representing your desired character(s). End by
scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and
not save
the entry string. You can then start again at the
beginning.
CANCEL
DEFAULT
50 = Length 2 is 50 Characters

Table of Contents

Other manuals for Datalogic Gryphon 2D Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Gryphon 2D Series and is the answer not in the manual?

Datalogic Gryphon 2D Series Specifications

General IconGeneral
BrandDatalogic
ModelGryphon 2D Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals