Enter/Exit Programming Mode Scanning Features
94 QuickScan™ Lite QW2400
Scanning Active Time
This setting specifies the amount of time that the reader stays in scan ON state
once the state is entered. The range for this setting is from 1 to 255 seconds in
1-second increments. See
"Scanning Active Time"
on page 254 for more detailed
programming instructions.
Stand Mode Flash
Enables/disables the LED flash when the reader is in Stand Mode.
$CSNET
Select Scanning Active Time Setting
To configure this feature, scan the ENTER/EXIT bar code
above, then the bar code at left followed by digits from
the Alphanumeric characters in
Appendix D, Keypad
representing your desired character(s). End by scanning
the ENTER/EXIT bar code agai
n.
Make a mistake? Scan the CANCEL bar code to abort and
not save
the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
005 = Scanning is active for 5 Seconds
$CSMFL00
Stand Mode Flash = Disable
$CSMFL01
Stand Mode Flash = Enable