Enter/Exit Programming Mode Case Conversion
80 QuickScan™ Lite QW2400
Case Conversion
This feature allows conversion of the case of all alphabetic characters to upper
or lower case.
Character Conversion
Character conversion is an eight byte configuration item. The eight bytes are 4
character pairs represented in hexadecimal ASCII values. The first character in
the pair is the character that will be converted. The second character in the pair
is the character to convert to. If the character to convert in a pair is FF, then no
conversion is done. See "Character Conversion" on
page 252 for more detailed
programming instructions.
NOTE
Case conversion affects ONLY s
canned bar code data, and does not affect
Label ID, Prefix, Suffix, or other appended data.
$CLFCA00
Case Conversion = Disable (no case conversion)
$CLFCA01
Case Conversion = Convert to upper case
$CLFCA02
Case Conversion = Convert to lower case
DEFAULT
$CLFCH
Configure Character Conversion

Table of Contents

Other manuals for Datalogic QuickScan Lite QW2400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic QuickScan Lite QW2400 and is the answer not in the manual?

Datalogic QuickScan Lite QW2400 Specifications

General IconGeneral
BrandDatalogic
ModelQuickScan Lite QW2400
CategoryBarcode Reader
LanguageEnglish

Related product manuals