Enter/Exit Programming Mode UPC-A
116 QuickScan™ Lite QW2400
Expand UPC-A to EAN-13
Expands UPC-A data to the EAN-13 data format. Selecting this feature also
changes the symbology ID to match those required for EAN-13.
UPC-A Number System Character Transmission
This feature enables/disables transmission of the UPC-A number system char-
acter.
$CAB3B00
UPC-A to EAN-13 = Don’t Expand
$CAB3B01
UPC-A to EAN-13 = Expand
DEFAULT
$CABNS00
UPC-A Number System Character = Do not transmit
$CABNS01
UPC-A Number System Character = Transmit
DEFAULT

Table of Contents

Other manuals for Datalogic QuickScan Lite QW2400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic QuickScan Lite QW2400 and is the answer not in the manual?

Datalogic QuickScan Lite QW2400 Specifications

General IconGeneral
IP RatingIP42
ConnectivityWired
Operating Temperature0 to 50 °C / 32 to 122 °F
Storage Temperature-40 to 70 °C / -40 to 158 °F
Light SourceRed LED
InterfaceUSB, RS-232
Drop Resistance1.5 m / 5 ft
Reading RangeUp to 30 cm / 11.8 in (depending on barcode density)
Dimensions6.7 x 2.8 x 2.6 in
Print Contrast Ratio25%
Decode Capability1D, 2D codes
Resolution4 mils
Depth of Field5 - 30 cm (depending on barcode density and type)
Power Supply5 VDC
Humidity5 to 95% (Non-condensing)