Enter/Exit Programming Mode Code 39
136 QuickScan™ Lite QW2400
Code 39 Check Character Calculation
Enable this option to enable/disable calculation and verification of an optional
Code 39 check character. When disabled, any check character in the label is
treated as a data character.
$CC3CC00
Code 39 Check Character Calculation = Don’t Calculate
$CC3CC01
Code 39 Check Character Calculation = Calculate Std Check
$CC3CC02
Code 39 Check Character Calculation = Calculate Mod 7
Check
$CC3CC04
Code 39 Check Character Calculation = Enable Italian Post
Check
$CC3CC08
Code 39 Check Character Calculation = Enable Daimler
Chrysler Check
DEFAULT

Table of Contents

Other manuals for Datalogic QuickScan Lite QW2400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic QuickScan Lite QW2400 and is the answer not in the manual?

Datalogic QuickScan Lite QW2400 Specifications

General IconGeneral
IP RatingIP42
ConnectivityWired
Operating Temperature0 to 50 °C / 32 to 122 °F
Storage Temperature-40 to 70 °C / -40 to 158 °F
Light SourceRed LED
InterfaceUSB, RS-232
Drop Resistance1.5 m / 5 ft
Reading RangeUp to 30 cm / 11.8 in (depending on barcode density)
Dimensions6.7 x 2.8 x 2.6 in
Print Contrast Ratio25%
Decode Capability1D, 2D codes
Resolution4 mils
Depth of Field5 - 30 cm (depending on barcode density and type)
Power Supply5 VDC
Humidity5 to 95% (Non-condensing)