EasyManuals Logo

Datalogic QuickScan Lite QW2400 User Manual

Datalogic QuickScan Lite QW2400
288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #164 background imageLoading...
Page #164 background image
Enter/Exit Programming Mode ABC Codabar
170 QuickScan™ Lite QW2400
ABC Codabar Dynamic Concatenation Timeout
This parameter specifies the timeout in 10-millisecond ticks used by the ABC
Codabar Dynamic Concatenation Mode. The timeout can be set within a range
of 05 to 255 in 10ms increments. A setting of zero specifies no delay.
ABC Codabar Force Concatenation
When ABC Codabar Concatenation is enabled and Force Concatenation is dis-
abled, both Codabar stand alone labels
and ABC Codabar concatenated labels
are transmitted. When ABC Codabar Concatenation is enabled and Force Con-
catenation is enabled only ABC Codabar concatenated labels are transmitted
wh
ile Codabar stand alone labels are not transmitted.
Force Concatenation has no effect if the ABC Codabar Concatenation is dis-
abled. The Force Concatenation mode has eff
ect both in Static and Dynamic
Concatenation Modes.
$CCBDT
Select ABC Codabar Dynamic Concatenation
Timeout Setting
To configure this feature, scan the ENTER/EXIT bar
code above, then the bar code at left followed by digits
from the Alphanumeric characters in
Appendix D,
Keypad
representing your desired character(s). End
by scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
10 = Quiet Interval of 200 ms
$CCBFC00
ABC Codabar Force Concatenation = Disable
$CCBFC01
ABC Codabar Force Concatenation = Enable
DEFAULT

Table of Contents

Other manuals for Datalogic QuickScan Lite QW2400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic QuickScan Lite QW2400 and is the answer not in the manual?

Datalogic QuickScan Lite QW2400 Specifications

General IconGeneral
IP RatingIP42
ConnectivityWired
Operating Temperature0 to 50 °C / 32 to 122 °F
Storage Temperature-40 to 70 °C / -40 to 158 °F
Light SourceRed LED
InterfaceUSB, RS-232
Drop Resistance1.5 m / 5 ft
Reading RangeUp to 30 cm / 11.8 in (depending on barcode density)
Dimensions6.7 x 2.8 x 2.6 in
Print Contrast Ratio25%
Decode Capability1D, 2D codes
Resolution4 mils
Depth of Field5 - 30 cm (depending on barcode density and type)
Power Supply5 VDC
Humidity5 to 95% (Non-condensing)