EasyManua.ls Logo

Datalogic QuickScan Lite QW2400 - BC412 Check Character Calculation; BC412 Length Control

Datalogic QuickScan Lite QW2400
288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Enter/Exit Programming Mode BC412
198 QuickScan™ Lite QW2400
BC412 Check Character Calculation
Enable this option to enable/disable calculation and verification of an optional
BC412 check character. When disabled, any check character in the label is
treated as a data character.
BC412 Length Control
This feature specifies either variable length decoding or fixed length decoding
for the BC412 symbology.
Variable Length:
For variable length decoding, a minimum and maximum length
may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
$CBCCC00
BC412 Check Character Calculation = Don’t Calculate
$CBCCC01
BC412 Check Character Calculation = Calculate Check Charac-
ter
DEFAULT
$CBCLC00
BC412 Length Control = Variable Length
$CBCLC01
BC412 Length Control = Fixed Length
DEFAULT