1D Symbologies Enter/Exit Programming Mode
Product Reference Guide
129
GS1 DataBar
Omnidirectional
The following options apply to the GS1 DataBar Omnidirectional (formerly RSS-
14) symbology.
GS1 DataBar Omnidirectional Enable/Disable
When disabled, the scanner will not read GS1 DataBar Omnidirectional bar
codes.
GS1 DataBar Omnidirectional GS1-128 Emulation
When enabled, GS1 DataBar Omnidirectional bar codes will be translated to the
GS1-128 label data format.
$C4BEN00
GS1 DataBar Omnidirectional = Disable
$C4BEN01
GS1 DataBar Omnidirectional = Enable
DEFAULT
$C4BU800
GS1 DataBar Omnidirectional GS1-128 Emulation =
Disable
$C4BU801
GS1 DataBar Omnidirectional GS1-128 Emulation = Enable
DEFAULT

Table of Contents

Other manuals for Datalogic QuickScan Lite QW2400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic QuickScan Lite QW2400 and is the answer not in the manual?

Datalogic QuickScan Lite QW2400 Specifications

General IconGeneral
IP RatingIP42
ConnectivityWired
Operating Temperature0 to 50 °C / 32 to 122 °F
Storage Temperature-40 to 70 °C / -40 to 158 °F
Light SourceRed LED
InterfaceUSB, RS-232
Drop Resistance1.5 m / 5 ft
Reading RangeUp to 30 cm / 11.8 in (depending on barcode density)
Dimensions6.7 x 2.8 x 2.6 in
Print Contrast Ratio25%
Decode Capability1D, 2D codes
Resolution4 mils
Depth of Field5 - 30 cm (depending on barcode density and type)
Power Supply5 VDC
Humidity5 to 95% (Non-condensing)