1D Symbologies Enter/Exit Programming Mode
Product Reference Guide
195
Code 93 Set Length 2
This feature specifies one of the bar code lengths for Code 93 Length Control
on page 193. Length 2 is the maximum label length if in Variable Length on
page 193 Mode, or the second fi
xed length if in Fixed Length on page 193
Mode. Length includes the bar code’s chec
k, data, and full-ASCII shift charac-
ters. The length does not include start/stop characters.
The length can be set from 1 to 50 characters. A setting of 00 specifies to
ig
nore this length (only one fixed length). See "Set Length 2" on
page 259 for
more detailed progr
amming instructions.
$CC9L2
Select Code 93 Length 2 Setting
To configure this feature, scan the ENTER/EXIT bar code
above, then the bar code at left followed by digits from
the Alphanumeric characters in
Appendix D, Key-
pad
representing your desired character(s). End by
scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
50 = Length 2 is 50 Characters

Table of Contents

Other manuals for Datalogic QuickScan Lite QW2400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic QuickScan Lite QW2400 and is the answer not in the manual?

Datalogic QuickScan Lite QW2400 Specifications

General IconGeneral
BrandDatalogic
ModelQuickScan Lite QW2400
CategoryBarcode Reader
LanguageEnglish

Related product manuals