Chapter 4 Parameters|
||
|
4-22 Revision 2016/03, 6ELE, V1.14
Overheat Warning
Applications
Purpose Functions
Related
Parameters
Air
conditioner
Safety
measure
When AC motor drive overheats, it uses a thermal sensor to have
overheat warning.
03.00
04.05~04.08
Two-wire/three-wire
Applications Purpose Functions
Related
Parameters
General
application
To run, stop, forward and
reverse by external
terminals
("CLOSE":FWD)
("CLOSE": REV)
DCM
FWD/STOP
REV/STOP
("CLOSE":RUN)
("CLOSE": REV)
DCM
RUN/STOP
FWD/REV
3-wire
MI3:("OPEN":STOP)
MI1 ("CLOSE":RUN):
MI2:("OPEN": FWD)
("CLOSE": REV)
DCM
REV/FWD
02.00
02.01
02.09
04.04
Operation Command
Applications Purpose Functions
Related
Parameters
General
application
Selecting the source of
control signal
Selection of AC motor drive control by external
terminals, digital keypad or RS485.
02.01
04.05~04.08
Frequency Hold
Applications Purpose Functions
Related
Parameters
General
application
Acceleration/ deceleration
pause
Hold output frequency during
Acceleration/deceleration
04.05~04.08
Auto Restart after Fault
Applications Purpose Functions
Related
Parameters
Air conditioners, remote
pumps
For continuous and
reliable operation
without operator
intervention
The AC motor drive can be restarted/reset
automatically up to 10 times after a fault
occurs.
08.15~08.16