Chapter 4 Parameters|
||
|
4-62 Revision 2016/03, 6ELE, V1.14
10 Current exceeds 2 times rated current during decel.(ocd)
11 Current exceeds 2 times rated current during steady state operation (ocn)
12
Ground fault (GFF)
13 Reserved
14 Phase-loss (PHL)
15 Reserved
16 Auto accel/decel failure (CFA)
17 Software/password protection (codE)
18 Power Board CPU WRITE Failure (cF1.0)
19 Power Board CPU READ Failure (cF2.0)
20 CC, OC Hardware protection failure (HPF1)
21 OV Hardware protection failure (HPF2)
22 GFF Hardware protection failure (HPF3)
23 OC Hardware protection failure (HPF4)
24 U-phase error (cF3.0)
25 V-phase error (cF3.1)
26 W-phase error (cF3.2)
27 DCBUS error (cF3.3)
28 IGBT Overheat (cF3.4)
29-31 Reserved
32 ACI signal error (AErr)
33 Reserved
34 Motor PTC overheat protection (PtC1)
35 FBE_ERR : PID feedback error (the signal of the feedback is wrong)
36 dEv: unusual PID feedback deviation
37-40 Reserved
In Pr.06.08 to Pr.06.12 the five most recent faults that occurred, are stored. After removing the cause of the
fault, use the reset command to reset the drive.