5. Troubleshooting
The Machine Does Not Run/Cannot Generate Output
Check Action Refer to
Is the front cover open? Keep the front cover closed during startup. For safety, the
initial operations are not performed if a cover is open when
the machine starts.
Is anything caught on the spindle
unit or rotary axis unit?
Temporarily turn the power o󰀨, and then check whether
something has become caught and is impeding initialization.
After you remove the obstruction, turn on the machine.
Is the milling bur caught on
anything?
It may not be possible to perform initialization if the milling bur
attached to the spindle unit is caught on the rotary axis unit or
workpiece. Try to detach the milling bur using the emergency
release function in VPanel.
"



The Operation Button Does Not Respond
Check Action Refer to
Is the front cover open? This machine restricts some operations when the front cover
is open. Close the front cover.
Are you wearing gloves? The built-in panel's operation button will not respond if you are
wearing gloves. Operate the button with a bare hand.
VPanel Does Not Recognize the Machine
Check Action Refer to
Is the driver installed correctly? If the connection to the computer is not made in the procedure
described, the driver may fail to install correctly. VPanel will
not function normally if the driver is not congured correctly.
Check again to ensure that the connection was made using
the correct procedure.
"




Did you verify the connection
procedure when connecting more
than one machine?
There is a possibility that the connection procedure was
performed incorrectly. Make sure that connections were
performed correctly. See the "Setup Guide" ("Connecting
Multiple Units").
"



Was the machine ID changed? When you change the machine ID, restart VPanel.
"



The Machine Recognized by VPanel Is Displayed as OFFLINE
Check Action Refer to
Is the cable connected? Make sure that the cables are connected.
""Setup Guide" ("Connecting the Cables")
Setup Guide
If the LAN cable is connected, are
there problems in the network
environment?
Contact the network administrator and revise the network
environment.