Replacing the Coolant
CAUTION
Do not overll or tilt the coolant tank.
The uid inlet on the coolant tank is open. Overlling or tilting will cause uid to spill out.
CAUTION
When raising or lowering the coolant tank, hold the position indicated in the following gure.
Failing to do so may result in your ngers being pinched, leading to injury.
When to Perform This Task
• Once a week
• When the following message is displayed in VPanel
Message
Important
Using coolant that is past its expiration date will decrease the durability of the lters�
Be sure to replace the coolant once per week or when instructed to do so by the message displayed in VPanel�
Items to Prepare Separately
• Water (soft or puried water)
This is required in order to make the coolant� Use soft or puried water� Using hard water may have a negative eect on the
service life of the milling bur and on the quality of the product�
• Additive (ZAW-1000D)
To make the coolant, you have to prepare the specied additive separately� To purchase additives, contact your authorized
DGSHAPE Corporation dealer or access our website (http://www�dgshape�com/)�
• Chelating reagent (ZCH-100D)
The ZCH-100D (hereinafter referred to as the "chelating reagent") works to make calcium and other substances contained in
water inactive� Including it in this product makes it easier to clean o milling powder that adheres to the machine and the
cutting tool after milling� To purchase chelating reagent, contact your authorized DGSHAPE Corporation dealer or access our
website (http://www�dgshape�com/)�
Periodic Care and Maintenance
61
3. Maintenance