Responding to Error Messages
167
5. Troubleshooting
"105E-0000" The pressure of the compressed air is too high or low.
Level 1
Situation/Error Cause
Compressed air is not being supplied
The regulator settings are incorrect�
Procedure
A
Adjust the regulator so that compressed air with the appropriate pressure (0.18 MPa to 0.22 MPa) can
be supplied.
" Setup Guide
B
According to the situation, perform the operations shown below.
When the error occurred during milling
Press the operation button on the built-in panel.
Milling will resume.
When the error occurred outside of milling
Hold down the operation button on the built-in panel.
This will clear the error.
"****-****" An unknown error occurred.
Level 3
Procedure
A
Turn o󰀨 the power.
B
Turn on the power.
If the Error Occurs Again
Contact your authorized Roland DG Corporation dealer.