Care of the Regulator Bowl
If the inside of the bowl becomes dirty, remove and wash the bowl�
WARNING
Be sure to bleed o󰀨 the air pressure before removing the regulator bowl.
Failure to do so may result in a rupture or components ying o󰀨.
WARNING
Before removing or attaching the regulator and before performing maintenance, make sure that the
bowl is securely attached.
If the bowl is not properly attached, it may come ying o󰀨 when compressed air is supplied.
WARNING
Clean the regulator bowl using a neutral detergent. Never use solvents such as gasoline, alcohol,
or thinner.
Using solvents may degrade the bowl and may result in a rupture.
Procedure
A
Stop the supply of compressed air.
B
Make sure that the pressure gauge reads "0."
C
Remove the regulator.
Loosen the screws indicated in the gure.
Periodic Care and Maintenance