Machine Problems
135
5. Troubleshooting
No Data Is Being Output to the Machine or the Machine Will Not Operate
Even Though Data Is Being Output
Check Action Refer to
Is the front cover open? If the front cover is open, the machine will not start milling
even if milling data is being received. Close the front cover,
and then press the built-in panel's operation button to start
milling.
Does VPanel recognize the
machine?
Verify that a message other than [OFFLINE] is shown in
VPanel.
If [OFFLINE] is shown in VPanel regardless of the machine
being on, check the cable connections and similar items.
If multiple machines are connected,
is the correct machine selected?
Select the machine to output milling data to on the VPanel
screen.
Is operation paused? When operation is paused, this is indicated in VPanel and
the PAUSE LED on the built-in panel lights in white. When
the machine is paused, milling stops and some operations
are restricted. Quickly pressing the built-in panel's operation
button of the machine will cancel the pause. Holding down the
operation button will abort milling.
Is initialization or a data cancel in
progress?
Milling data received during the initial operations or during a
data cancel will be cancelled. Make sure to output milling data
after conrming that [READY] is displayed for the machine's
operation status in the VPanel top window.
Is the milling data correct? There may be problems in the milling data parameters. Check
the milling data.
Has an error occurred? The error LED will ash if an error occurs. A description of the
error is displayed in VPanel.
The Computer Shuts Down When Connecting Multiple Machines
Check Action Refer to
Are machines with the same ID
connected to the computer at the
same time?
Connecting more than one machine with the same ID to a
computer at the same time may cause the computer to shut
down. If the computer shuts down, turn o󰀨 the power of all
connected machines, and then disconnect the USB cables
from the computer.
Restart the computer, and then start VPanel. If VPanel will not
start, reinstall it. After that, congure the settings so that no
machines are assigned the same ID.
"




Compressed Air Does Not Come Out
Check Action Refer to
Is the power switched on? Compressed air is not supplied when the power is o󰀨.
Is the regulator properly connected
and are the pressure settings
correctly congured?
Check the connection. If there are no connection problems,
check whether the regulator scale indicates zero. If the set
pressure of the regulator is zero, compressed air will not be
supplied.
" "Setup Guide" ("Preparing the Regulator")
Is the compressed air supply hose
bent or attened?
If the hose is bent or attened, straighten it to enable the ow
of compressed air. Replace the hose if it has deteriorated to
the point that air does not pass through it.