Responding to Error Messages
159
5. Troubleshooting
"1023-0000 to 1028-0000" Milling data error.
Level 2
• 1023-0000: Milling data error. The number of parameters is incorrect.
• 1024-0000: Milling data error. The parameter is out of range.
• 1025-0000: Milling data error. A wrong command is detected.
• 1026-0000: Milling data error. The address is not dened.
• 1027-0000: Milling data error. The parameter is not dened.
• 1028-0000: Milling data error. The operation cannot be executed.
Situation/Error Cause
• There is a problem with the milling data received from the computer�
• The data transfer has failed due to the computer being under a high load�
Procedure
A
Hold down the operation button on the built-in panel.
This will clear the error.
B
Check the milling data.
If necessary check the CAM settings and the shape in the CAD data.
If there are no problems with the milling data
1 Exit any applications that are not being used.
2 Restart the computer.
3 Perform milling again.