EasyManua.ls Logo

DGSHAPE DWX-42W - 1023-0000 to 1028-0000 Milling Data Error

DGSHAPE DWX-42W
169 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Responding to Error Messages
159
5. Troubleshooting
"1023-0000 to 1028-0000" Milling data error.
Level 2
1023-0000: Milling data error. The number of parameters is incorrect.
1024-0000: Milling data error. The parameter is out of range.
1025-0000: Milling data error. A wrong command is detected.
1026-0000: Milling data error. The address is not dened.
1027-0000: Milling data error. The parameter is not dened.
1028-0000: Milling data error. The operation cannot be executed.
Situation/Error Cause
There is a problem with the milling data received from the computer
The data transfer has failed due to the computer being under a high load�
Procedure
A
Hold down the operation button on the built-in panel.
This will clear the error.
B
Check the milling data.
If necessary check the CAM settings and the shape in the CAD data.
If there are no problems with the milling data
1 Exit any applications that are not being used.
2 Restart the computer.
3 Perform milling again.

Table of Contents