"1022-000*" The % milling bur was not found.
* The milling bur stocker number (1 to 7) is displayed for %�
Level 1
Situation/Error Cause 1
The milling bur has not been set�
The milling bur has been set in an incorrect stocker number
Procedure
A
Set the milling bur in the correct position.
B
According to the situation, perform the operations shown below.
When the error occurred during milling
Press the operation button on the built-in panel.
Milling will resume.
When the error occurred outside of milling
Hold down the operation button on the built-in panel.
This will clear the error.
Situation/Error Cause 2
The ATC magazine is out of position�
Procedure
Perform automatic correction.
" 
If the Error Occurs Again
The collet may have worn out� Replace the collet�
" 
If the error occurs again even after you replace the collet, replace the spindle unit� To replace the spindle unit, contact your
authorized Roland DG Corporation dealer