EasyManua.ls Logo

DGSHAPE DWX-42W - Milling Quality Problems; The Milling Results Are Not Attractive; There Is a Line of Level Difference in the Milling Results; The Dimensions of the Milling Results Do Not Match

DGSHAPE DWX-42W
169 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
137
5. Troubleshooting
Milling Quality Problems
The Milling Results Are Not Attractive
Check Action Refer to
Is the workpiece rmly secured in
place?
Check the mounting condition of the workpiece. Fasten the
workpiece in place securely so that it will not slip out of place
or come loose because of milling bur pressure or vibration
during milling.
Is the milling bur worn? If the same milling bur is used for milling for a long period
of time, it will become worn and a󰀨ect milling results. Try
replacing the milling bur with a new one. The work time of the
milling bur can also be managed in VPanel.
Are the milling conditions too
strict?
Strict milling conditions may a󰀨ect milling results. Review the
CAM milling conditions.
Is the machine out of correction? The origin point may become out of position due to prolonged
use or relocating the machine, which can result in a line
of level di󰀨erence. Perform automatic correction. If the
expected results cannot be obtained even after performing
automatic correction, perform manual correction. With manual
correction, changing the Y value in Origin point may improve
the situation.
There Is a Line of Level Di󰀨erence in the Milling Results
Check Action Refer to
Correction may be necessary. The origin point may become out of position due to prolonged
use or relocating the machine, which can result in a line
of level di󰀨erence. Perform automatic correction. If the
expected results cannot be obtained even after performing
automatic correction, perform manual correction. With manual
correction, changing the Y value in Origin point may improve
the situation.
Are the CAM milling conditions
correct?
Incorrect CAM milling settings may lead to line of level
di󰀨erences. Review the CAM milling conditions.
The Dimensions of the Milling Results Do Not Match
Check Action Refer to
Does the milling bur diameter match
the CAM settings?
Check the CAM settings.
Does the set temperature of the
sintering program match the
workpiece?
Check the set temperature of the sintering program to see if it
matches the workpiece of the manufacturer used.

Table of Contents