Responding to Error Messages
152
5. Troubleshooting
"1000-****" The % limit switch was not found.
* The name of the axis (X, Y, Z, A, or a combination of these axes) is displayed for %�
Level 3
Situation/Error Cause
• Operation is inhibited by milling waste or an obstruction�
Procedure
A
Turn o the power.
B
Remove any objects blocking operation of the machine and any accumulated milling waste.
C
Turn on the power, and then resume operation.
"1006-02**" The % axis position has been shifted.
* The name of the axis (X, Y, Z, A, or a combination of these axes) is displayed for %�
Level 2
Situation/Error Cause 1
• Operation is inhibited by milling waste or an obstruction, and the motor position has been lost�
Procedure
A
Remove any objects blocking operation of the machine and any accumulated milling waste.
B
Hold down the operation button on the built-in panel.
This will clear the error.
Situation/Error Cause 2
• The milling conditions are too strict�
Procedure
A
Hold down the operation button on the built-in panel.
This will clear the error.
B
Review the CAM settings and the shape specied in the CAD data.