8 | Components description
120 AXH1230‐UK ﴾ENG﴿ ‐ Apollo KM
CODE COMPONENT ALARM
190.E4 TransmissionDisconnect
Command
Not commanded but a current consumption exceeding the
threshold has been detected
(ControlUnitMalfunction)
192.E4 Output commanded but the control unit detects a high
consumption
(ControlUnitorDistributorMalfunction)
200.E4 ExtensionOUTdistributor
solenoidvalvecommand
Not commanded but a current consumption exceeding the
threshold has been detected
(ControlUnitMalfunction)
201.E4 Commanded but the control unit does not detect a current
consumption exceeding the threshold (Control Unit or
DistributorMalfunction)
202.E4 Output commanded but the control unit detects a high
consumption
(ControlUnitorDistributorMalfunction)
210.E4 ExtensionINdistributor
solenoidvalvecommand
Not commanded but a current consumption exceeding the
threshold has been detected
(ControlUnitMalfunction)
211.E4 Commanded but the control unit does not detect a current
consumption exceeding the threshold (Control Unit or
DistributorMalfunction)
212.E4 Output commanded but the control unit detects a high
consumption
(ControlUnitorDistributorMalfunction)
220.E4 AuxiliarydistributorA
solenoidvalvecommand
Not commanded but a current consumption exceeding the
threshold has been detected
(ControlUnitMalfunction)
221.E4 Commanded but the control unit does not detect a current
consumption exceeding the threshold (Control Unit or
DistributorMalfunction)
222.E4 Output commanded but the control unit detects a high
consumption
(ControlUnitorDistributorMalfunction)
230.E4 AuxiliarydistributorB
solenoidvalvecommand
Not commanded but a current consumption exceeding the
threshold has been detected
(ControlUnitMalfunction)
231.E4 Commanded but the control unit does not detect a current
consumption exceeding the threshold (Control Unit or
DistributorMalfunction)
232.E4 Output commanded but the control unit detects a high
consumption
(ControlUnitorDistributorMalfunction)
240.E4 Hydraulicpowerfunction Output not commanded but a too high current consumption
hasbeendetected
242.E4 Outputcommandedbutananomalouscurrentconsumptionor
ashortcircuithavebeendetected