AssuredSAN 4004 Series Setup Guide 77
1
Your server or laptop configuration determines which COM port is used for Disk Array USB Port.
2
Verify the appropriate COM port for use with the CLI.
5. In the terminal emulator, connect to controller A.
6. Press Enter to display the CLI prompt (#).
The CLI displays the system version, MC version, and login prompt:
a. At the login prompt, enter the default user manage.
b. Enter the default password
!manage.
If the default user or password — or both — have been changed for security reasons, enter the secure
login credentials instead of the defaults shown above.
NOTE: The following CLI commands enable you to set the management mode to v3 or v2:
•Use set protocols to change the default management mode.
•Use set cli-parameters to change the current management mode for the CLI session.
See the CLI Reference Guide for more information.
7. At the prompt, enter the following command to set the values you obtained in step 1 for each Network
port, first for controller A, and then for controller B:
set network-parameters ip address netmask netmask gateway gateway
controller a|b
where:
address is the IP address of the controller
netmask is the subnet mask
gateway is the IP address of the subnet router
a|b specifies the controller whose network parameters you are setting
For example:
# set network-parameters ip 192.168.0.10 netmask 255.255.255.0 gateway
192.168.0.1 controller a
# set network-parameters ip 192.168.0.11 netmask 255.255.255.0 gateway
192.168.0.1 controller b
Table 6 Terminal emulator display settings
Parameter Value
Terminal emulation mode VT-100 or ANSI (for color support)
Font Terminal
Translations None
Columns 80
Table 7 Terminal emulator connection settings
Parameter Value
Connector COM3 (for example)
1, 2
Baud rate 115,200
Data bits 8
Parity None
Stop bits 1
Flow control None