Setup
Operating Instructions 581 - 01.0 - 05/2016148
2. Connect the valve (4) to the hose (5) for the suction container.
3. Connect the connection hose (6) for the compressed air to
th
e valve (4).
7.13.2 Setting the operating pressure
Information
The operating pressure is 6.5 bar.
The operating pressure is preset
and cannot be adjusted.
7.14 Checking the lubrication
The wicks, felt, looper and needle bar must all be lubricated with
a little oil when setting up the machine, or after longer standstill
periods.
All moving parts in the machine are lubricated via an oil-wick
system
from 2 oil reservoirs.
Use only DA 10 lub
ricant or an equivalent oil conforming to the
following specifications for lubrication:
• Viscosity at 40° C: 10 mm²/s
• Flash point: 150° C
CAUTION
Risk of environmental damage from oil!
Oil is a pollutant and must not enter the sewage
system
or the soil.
Carefully collect up used oil.
Dispose of used oil and oily machine parts in
a
ccordance with the legal regulations.