MAINTENANCE, SERVICE AND FAULT FINDING
4-46 25364 Issue 8 March 2018
1065 Not Enough Space on
System Disk
Reserved
1066 Not Enough Space Reserved
1070 Unable to open log
file
The log file could not be opened.
If the log is located on the LAN check
access rights.
1071 Unable to rename Log
file
The log file could not be renamed.
If the log is located on the LAN check
access rights.
1072 Unable to delete old
Log file
The log file could not be deleted.
If the log is located on the LAN check
access rights.
1074 Maximum log size
reached
Reserved
1075 Could not write to log
because of this error:
See the remaining text on the display.
1076 Unable to get file
status
The file status could not be obtained.
If the log is located on the LAN check
access rights.
1077 Unable to create log
sub dir
The log sub dir could not be created.
If the log is located on the LAN check
access rights.
1078 Unable to access
Network log file
The network file could not be
accessed. If the log is located on the
LAN check access rights.
1079 Recursive log write,
log disabled
Error in firmware. Contact supplier and
supply information on how the error
occurred.
1080 Image not found The image could not be found. Check
the filename (If design is saved on
network by EasyDesign check the
Save to SRAM field).
If the filename is generated by a
variable check that the variable yields
the correct path/name.
1081 Image Not
Monochrome
The controller only supports images
with 1 bit per pixel (Black/white no
greyscale).
1082 Invalid Graphic File Check if the file exists. It is either
damaged or incompatible with the
controller.
Error No. Error Text Action