C
HAPTER
40
| CFM Commands
Defining CFM Structures
– 1327 –
show ethernet cfm
maintenance-points
local
This command displays the maintenance points configured on this device.
SYNTAX
show ethernet cfm maintenance-points local
{mep [domain domain-name | interface interface |
level level-id] | mip [domain domain-name | level level-id]}
mep – Displays only local maintenance end points.
mip – Displays only local maintenance intermediate points.
domain-name – Domain name. (Range: 1-43 alphanumeric
characters)
interface – Displays CFM status for the specified interface.
ethernet unit/port
unit - Unit identifier. (Range: 1)
port - Port number. (Range: 1-28/52)
port-channel channel-id (Range: 1-16)
level-id – Maintenance level for this domain. (Range: 0-7)
DEFAULT SETTING
None
COMMAND MODE
Privileged Exec
COMMAND USAGE
◆ Use the mep keyword with this command to display the MEPs
configured on this device as DSAPs through the ethernet cfm mep
command.
◆ Using the mip keyword with this command to display the MIPs
generated on this device by the CFM protocol when the mip-creation
method is set to either “default” or “explicit” by the ethernet cfm
domain command or the ma index name command.
EXAMPLE
This example shows all MEPs configured on this device for maintenance
domain rd.
Console#show ethernet cfm maintenance-points local mep
MPID MD Name Level Direct VLAN Port CC Status MAC Address
---- ---------------- ----- ------ ---- -------- --------- -----------------
1 rd 0 UP 1 Eth 1/ 1 Enabled 00-12-CF-3A-A8-C0
Console#