C
HAPTER
40
| CFM Commands
Fault Generator Operations
– 1348 –
notification generator state machine has been reset, and repeat those
steps until the fault is resolved.
â—† Only the highest priority defect currently detected is reported in the
fault alarm.
â—† Priority defects include the following items:
EXAMPLE
This example sets the lowest priority defect that will generate a fault
alarm.
Console(config)#ethernet cfm domain index 1 name voip level 3
Console(config-ether-cfm)#mep fault-notify lowest-priority 1
Console(config-ether-cfm)#
Table 184: Remote MEP Priority Levels
Priority Level Level Name Description
1 allDef All defects.
2 macRemErrXcon DefMACstatus, DefRemoteCCM, DefErrorCCM, or
DefXconCCM.
3 remErrXcon DefErrorCCM, DefXconCCM or DefRemoteCCM.
4 errXcon DefErrorCCM or DefXconCCM.
5xconDefXconCCM
6 noXcon No defects DefXconCCM or lower are to be
reported.
Table 185: MEP Defect Descriptions
Field Description
DefMACstatus Either some remote MEP is reporting its Interface Status TLV as
not isUp, or all remote MEPs are reporting a Port Status TLV that
contains some value other than psUp.
DefRemoteCCM The MEP is not receiving valid CCMs from at least one of the
remote MEPs.
DefErrorCCM The MEP has received at least one invalid CCM whose CCM
Interval has not yet timed out.
DefXconCCM The MEP has received at least one CCM from either another MAID
or a lower MD Level whose CCM Interval has not yet timed out.