C
HAPTER
40
| CFM Commands
Fault Generator Operations
– 1349 –
mep fault-notify
reset-time
This command configures the time after a fault alarm has been issued, and
no defect exists, before another fault alarm can be issued. Use the no form
to restore the default setting.
SYNTAX
mep fault-notify reset-time reset-time
no fault-notify reset-time
reset-time – The time that must pass without any further defects
indicated before another fault alarm can be generated.
(Range: 3-10 seconds)
DEFAULT SETTING
10 seconds
COMMAND MODE
CFM Domain Configuration
EXAMPLE
This example sets the reset time after which another fault alarm can be
generated.
Console(config)#ethernet cfm domain index 1 name voip level 3
Console(config-ether-cfm)#mep fault-notify reset-time 7
Console(config-ether-cfm)#
show ethernet cfm
fault-notify-
generator
This command displays configuration settings for the fault notification
generator.
SYNTAX
show ethernet cfm fault-notify-generator mep mpid
mpid – Maintenance end point identifier. (Range: 1-8191)
DEFAULT SETTING
None
COMMAND MODE
Privileged Exec
EXAMPLE
This example shows the fault notification settings configured for one MEP.
Console#show ethernet cfm fault-notify-generator mep 1
MD Name MA Name Highest Defect Lowest Alarm Alarm Time Reset Time
------------ ------------ -------------- ------------- ---------- ----------
voip rd none macRemErrXcon 3sec. 10sec.
Console#