EasyManuals Logo

Edge-Core ECS3510-52T User Manual

Edge-Core ECS3510-52T
1474 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1340 background imageLoading...
Page #1340 background image
C
HAPTER
40
| CFM Commands
Link Trace Operations
– 1340 –
â—† The cross-check process is disabled by default, and must be manually
started using this command with the enable keyword.
EXAMPLE
This example enables cross-checking within the specified maintenance
association.
Console#ethernet cfm mep crosscheck enable md voip ma rd
Console#
show ethernet cfm
maintenance-points
remote crosscheck
This command displays information about remote MEPs statically
configured in a cross-check list.
SYNTAX
show ethernet cfm maintenance-points remote crosscheck
[domain domain-name | mpid mpid]
domain-name – Domain name. (Range: 1-43 alphanumeric
characters)
mpid – Maintenance end point identifier. (Range: 1-8191)
DEFAULT SETTING
None
COMMAND MODE
Privileged Exec
EXAMPLE
This example shows all remote MEPs statically configured on this device.
Console#show ethernet cfm maintenance-points remote crosscheck
MPID MA Name Level VLAN MEP Up Remote MAC
---- -------------------- ----- ---- ------ ------------------
2 downtown 4 2 Yes 00-0D-54-FC-A2-73
Console#
Link Trace Operations
ethernet cfm
linktrace cache
This command enables caching of CFM data learned through link trace
messages. Use the no form to disable caching.
SYNTAX
[no] ethernet cfm linktrace cache
DEFAULT SETTING
Enabled

Table of Contents

Other manuals for Edge-Core ECS3510-52T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edge-Core ECS3510-52T and is the answer not in the manual?

Edge-Core ECS3510-52T Specifications

General IconGeneral
BrandEdge-Core
ModelECS3510-52T
CategoryNetwork Router
LanguageEnglish

Related product manuals