C
HAPTER
41
| OAM Commands
– 1355 –
detected, fan failure, CRC error in flash memory, insufficient memory,
or other hardware faults.
◆ Dying gasp events are caused by an unrecoverable failure, such as a
power failure or device reset.
N
OTE
:
When system power fails, the switch will always send a dying gasp
trap message prior to power down.
EXAMPLE
Console(config)#interface ethernet 1/1
Console(config-if)#efm oam critical-link-event dying-gasp
Console(config-if)#
efm oam
link-monitor frame
This command enables reporting of errored frame link events. Use the no
form to disable this function.
SYNTAX
[no] efm oam link-monitor frame
DEFAULT SETTING
Enabled
COMMAND MODE
Interface Configuration
COMMAND USAGE
◆ An errored frame is a frame in which one or more bits are errored.
◆ If this feature is enabled and an errored frame link event occurs, the
local OAM entity (this switch) sends an Event Notification OAMPDU.
EXAMPLE
Console(config)#interface ethernet 1/1
Console(config-if)#efm oam link-monitor frame
Console(config-if)#