Page #1355 background image
C
HAPTER
41
| OAM Commands
– 1355 –
detected, fan failure, CRC error in flash memory, insufficient memory,
or other hardware faults.
â—† Dying gasp events are caused by an unrecoverable failure, such as a
power failure or device reset.
N
OTE
:
When system power fails, the switch will always send a dying gasp
trap message prior to power down.
EXAMPLE
Console(config)#interface ethernet 1/1
Console(config-if)#efm oam critical-link-event dying-gasp
Console(config-if)#
efm oam
link-monitor frame
This command enables reporting of errored frame link events. Use the no
form to disable this function.
SYNTAX
[no] efm oam link-monitor frame
DEFAULT SETTING
Enabled
COMMAND MODE
Interface Configuration
COMMAND USAGE
â—† An errored frame is a frame in which one or more bits are errored.
â—† If this feature is enabled and an errored frame link event occurs, the
local OAM entity (this switch) sends an Event Notification OAMPDU.
EXAMPLE
Console(config)#interface ethernet 1/1
Console(config-if)#efm oam link-monitor frame
Console(config-if)#

Table of Contents

Other manuals for Edge-Core ECS3510-52T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edge-Core ECS3510-52T and is the answer not in the manual?

Edge-Core ECS3510-52T Specifications

General IconGeneral
BrandEdge-Core
ModelECS3510-52T
CategoryNetwork Router
LanguageEnglish

Related product manuals