swMemoryUtiRisingThreshold
Notification
1.3.6.1.4.1.259.10.1.27.2.1.0.109 This notification indicates that the memory
utilization has risen from
memoryUtiFallingThreshold to
memoryUtiRisingThreshold.
swMemoryUtiFallingThreshold
Notification
1.3.6.1.4.1.259.10.1.27.2.1.0.110 This notification indicates that the memory
utilization has fallen from
memoryUtiRisingThreshold to
memoryUtiFallingThreshold.
dhcpRougeServerAttackTrap 1.3.6.1.4.1.259.10.1.27.2.1.0.114 This trap is sent when receiving a DHCP packet
from a rouge server.
macNotificationTrap 1.3.6.1.4.1.259.10.1.27.2.1.0.138 This trap is sent when there are changes of the
dynamic MAC addresses on the switch.
lbdDetectionTrap 1.3.6.1.4.1.259.10.1.27.2.1.0.141 This trap is sent when a loopback condition is
detected by LBD.
lbdRecoveryTrap 1.3.6.1.4.1.259.10.1.27.2.1.0.142 This trap is sent when a recovery is done by LBD.
sfpThresholdAlarmWarnTrap 1.3.6.1.4.1.259.10.1.27.2.1.0.189 This trap is sent when the SFP's A/D quantity is
not within alarm/warning thresholds.
userAuthenticationFailureTrap 1.3.6.1.4.1.259.10.1.27.2.1.0.199 This trap will be triggered if authentication fails.
userAuthenticationSuccessTrap 1.3.6.1.4.1.259.10.1.27.2.1.0.200 This trap will be triggered if authentication is
successful.
loginTrap 1.3.6.1.4.1.259.10.1.27.2.1.0.201 This trap is sent when user logs in.
logoutTrap 1.3.6.1.4.1.259.10.1.27.2.1.0.202 This trap is sent when user logs out.
fileCopyTrap 1.3.6.1.4.1.259.10.1.27.2.1.0.208 This trap is sent when file copy is executed.
If the copy action is triggered by the system, the
login user information (trapVarLoginUserName/
trapVarSessionType/
trapVarLoginInetAddressTypes/
trapVarLoginInetAddres) will be null values.
* These are legacy notifications and therefore must be enabled in conjunction with the corresponding traps on the SNMP
Configuration menu.
Table 31: Supported Notification Messages (Continued)
Model Level Group

Table of Contents

Other manuals for Edge-Core ECS3510-52T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edge-Core ECS3510-52T and is the answer not in the manual?

Edge-Core ECS3510-52T Specifications

General IconGeneral
BrandEdge-Core
ModelECS3510-52T
CategoryNetwork Router
LanguageEnglish

Related product manuals