148
Out 1 and 2 - SSROut 1 and 2 - SSR
Out 1 and 2 - SSROut 1 and 2 - SSR
Out 1 and 2 - SSR
Type: notType: not
Type: notType: not
Type: not isolated voltage output
- Logic level 1:
14V @ 20 mA max.
24 V @ 1 mA.
- Logic level 0:
< 0.5 V D.C.
Out 1 and 2 - TRIACOut 1 and 2 - TRIAC
Out 1 and 2 - TRIACOut 1 and 2 - TRIAC
Out 1 and 2 - TRIAC
Switching modeSwitching mode
Switching modeSwitching mode
Switching mode: isolated zero crossing type.
Rated currentRated current
Rated currentRated current
Rated current: from 50 mA to 1 A.
Rated voltageRated voltage
Rated voltageRated voltage
Rated voltage: from 24 V
RMS
to 240 V
RMS
-10% +15% (50-60
Hz).
Load typeLoad type
Load typeLoad type
Load type: resistive load only
II
II
I
22
22
2
t for external fuset for external fuse
t for external fuset for external fuse
t for external fuse: 128
Out 3 and 4Out 3 and 4
Out 3 and 4Out 3 and 4
Out 3 and 4
FunctionFunction
FunctionFunction
Function: singularly programmable as:
- Control output
- Alarm output
- Event output.
- Servomotor drive (Out 3 , out 4 )
TypeType
TypeType
Type: Relay .
Relay typeRelay type
Relay typeRelay type
Relay type: SPST
Contact ratingContact rating
Contact ratingContact rating
Contact rating: 3 A @ 250 V on resistive load.
NotesNotes
NotesNotes
Notes:
1) The commons of the out 3 and 4 are connected together
with the same rear terminal.
2) When OUT 3 and 4 are used as independent relay outputs
the addition of the two currents must not exceed 3 A.
Servomotor outputServomotor output
Servomotor outputServomotor output
Servomotor output
TypeType
TypeType
Type: Two relays with interlocked contact (Out 3 and 4).
Servomotor output type:Servomotor output type:
Servomotor output type:Servomotor output type:
Servomotor output type:
- Close loop
- Open loop with valve position indication
- Open loop.
Feedback potentiometer inputFeedback potentiometer input
Feedback potentiometer inputFeedback potentiometer input
Feedback potentiometer input: from 100 Ω to 10 kΩ.
Servomotor travel timeServomotor travel time
Servomotor travel timeServomotor travel time
Servomotor travel time: From 12 s to 3 minutes.
Servomotor dead bandServomotor dead band
Servomotor dead bandServomotor dead band
Servomotor dead band: From 1 % to 50 % of the feedback
span or of the valve travel time.
Analog outputsAnalog outputs
Analog outputsAnalog outputs
Analog outputs
Out 5 and 6Out 5 and 6
Out 5 and 6Out 5 and 6
Out 5 and 6
FunctionFunction
FunctionFunction
Function: Programmable as
- Control output
- Analog retransmission of the measured value
- Analog retransmission of the operative set point.
XKP-1-D1.pmd 25/05/2006, 11.28148