48
CnF. 4CnF. 4
CnF. 4CnF. 4
CnF. 4
- Secondary output auxiliary conditioning- Secondary output auxiliary conditioning
- Secondary output auxiliary conditioning- Secondary output auxiliary conditioning
- Secondary output auxiliary conditioning
- [C.F17]- [C.F17]
- [C.F17]- [C.F17]
- [C.F17]
This parameter will be available only when secondary control
output is configured and “SC.Cn” ("Secondary control output
conditioning" [C.F12]) is different from “norñ”.
Range:bEFr = The functions listed at Note (**) are calculated
before before
before before
before to apply the action selected by “SC.Cn”
("Secondary control output conditioning"
[C.F12]) parameter.
AFtr = The functions listed at Note (**) are calculated
after after
after after
after to apply the action selected by “SC.Cn”
(“Secondary control output conditioning”
[C.F12]) parameter.
Note (**)Note (**)
Note (**)Note (**)
Note (**)
- "Secondary control output limiters" - for more details see
[r.E08] and [r.E09] parameters.
- "Secondary control output max rate of rise" (see [r.E10]).
- "Secondary control output display value" - for more details
see "Display function during programmer mode" paragraph
at pag. 106 and [C.F13], [C.F14], [C.F15] and [C.F16]
parameters.
- "Threshold for alarm on control output value" - for more
details see [r.F01], [r.F05] [r.F09] and [r.F13] parameters.
- The secondary control output value displayed by bargraph.
General note about configuration group 3General note about configuration group 3
General note about configuration group 3General note about configuration group 3
General note about configuration group 3
Exiting from the configuration group 3 the instrument automati-
cally tests the "SPLt" parameter (Split range [C.F01]). When
"SPLt." parameter is enabled (= "Enb"), the instrument
performs the following actions:
1) If “Añ.UL” parameter ("Output value for AUTO to MAN
transfer [C.G04]) is lower than 0, it will be forced to “buñ“.
2) If the “SF.UL” parameter ("Output safety value" [C.G10])
is lower than zero, it will be forced to zero.
3) If the “IP” parameter ("Integral pre-load" [r.d05] is lower than
zero, it will be forced to 50.0.
CnF. 3CnF. 3
CnF. 3CnF. 3
CnF. 3