3. INSPECTION AND PREPARATION
3.2 ARRANGEMENT OF ELECTRICAL CABLES
!
Before performing any operation on the system, disconnect the power
supply.
The electrical system must be compliant with the regulations in force in
the Country of installation (EN 60335-1...)
The power mains of the automation must be fitted with a multi-pole
power switch with a switch-contact gap of at least 3 mm. It is advisable
to use a 6A circuit breaker with a multi-pole power switch.
Ensure there is a residual current device with a 0.03 A threshold upstream
of the system.
Ensure the earthing system is constructed in a workmanlike manner and
connect the structure’s metal parts to it.
Lay the electrical cables for connecting the accessories and the electri-
cal power supply 3.
Protect cables by means of suitable ducting.
!
Place control accessories within the automations visual range. These
devices must always be accessible, even with the door open.
Comply with the following heights from the ground:
- control accessories = minimum 150 cm
- emergency buttons = max 120 cm
3.1 PRELIMINARY INSPECTION
!
Prior to installation, check soundness of the load bearing masonry struc-
ture and door. Perform any required work to assure:
- solidity, stability and absence of any risk of detachment or collapse of
the masonry structure, fixed door frame and automation
- level flooring, without any friction/hindrance to smooth leaf sliding
- absence of sharp edges (cutting hazard)
- absence of protruding parts (hooking/entrainment hazard)
1 Internal monitored opening detector and safe closing (XV1/XDT1) included in the supply
2 External monitored opening detector and safe closing (XV1/XDT1) optional accessory
3 SDK EVO optional accessory
4 Key switch to lock the SDK EVO optional accessory
5 Emergency/Key/OPEN control buttons optional accessories
6 Power supply 230V~
7 Internal monitored detec tors for safe opening (XBFA) optional accessory
230V~
external
internal