EasyManua.ls Logo

FAAC A1000 - 16. Operations on the Board; 16.1 System Setup; 16.2 Reset Procedure; 16.3 Restoring Factory Status

FAAC A1000
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A1000 71 532210 04 - Rev.A
Translation of the original instructions
ENGLISH
16. OPERATIONS ON THE BOARD
16.1 SETUP
The SETUP consists of a series of movements.
WHEN IS SETUP NECESSARY
- when the door automation is first put into operation 53 or
after replacing the board
- when the display indicates error
15
15
- following any travel variation
- when leaf number (LN) is modified
- after a reset to factory settings
SETUP CANNOT be performed in conditions of:
- Emergency active
- MANUAL mode
- NIGHT-TIME mode
- Power outage.
In this case the board remains in
L0
L0 status until the cause of the
problem has been removed.
HOW TO PERFORM SETUP FROM BOARD
- To perform SETUP from board press button SW1 for 5 s.
0.0
RESET/SETUP
DL2
+
-
F
J
L0...L1...
L0...L1...
L2
L2
...
...
5 s
SW1
SETUP/RESET
SETUP is interrupted (status
L0
L0 ) if one of the following occurs during
the procedure:
- activation of an emergency command
- setting NIGHT-TIME or MANUAL mode
- activation of an error during motion.
- Activation of the safeties does not prevent SETUP execution.
To perform the SETUP using SDK EVO refer to 91.
16.2 RESET
Reset is an initialising procedure of board operation.
WHEN IS RESET NECESSARY
After automation lock due to:
- a board error with a RESET request
HOW TO PERFORM A RESET FROM THE BOARD
- Press the RESET button SW1 for 1 s and release it.
0.0
RESET/SETUP
DL2
+
-
F
J
SW1
SETUP/RESET
1 s
To perform a RESET using SDK EVO, refer to 69.
16.3 RESTORING FACTORY STATUS
RESTORE brings all board parameters back to factory status.
!
The procedure is irreversible and involves:
- loss of data acquired from SETUP (need to perform SETUP again)
- loss of programming (resetting default values)
- relevant cycle counters are reset to zero
- loss of passwords (“0000” is reset)
WHEN IS RESTORE NECESSARY
When you wish to cancel all settings made on the board.
HOW TO PERFORM RESTORE
1. Disconnect mains power supply and disconnect the emergency
battery
2. restore power supply to the board
3. within the first 4 s after switching on (while the display shows the
FW version) press simultaneously for about 5 s the buttons +
-
F
F
+
-
5 s
4. The display indicates
--
--
5. release the buttons
6. the display shows automation status.
!
After restoring factory status perform SETUP.