EasyManuals Logo

FAAC A1000 User Manual

FAAC A1000
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #88 background imageLoading...
Page #88 background image
A1000 88 532210 04 - Rev.A
OK
OK
OK
OK
OK
OK
OK
ENGLISH
ITALIANO
FRANÇAIS
DEUTSCH
ESPANOL
NEDERLANDS
Translation of the original instructions
ENGLISH
MENU 1 LANGUAGE
Default: ENGLISH
INPUTS / OUTPUTS
OK
OK
INPUTS / OUTPUTS
2
PROGRAMMING
2 Inputs I1- I4
1. Select an input from the list:
- I1
- I2
- I3
- I4
2. Select function:
-
-
Disabled (0)
Disabled (0)
-
-
Open external (1)
Open external (1)
-
-
Open internal (4)
Open internal (4)
-
-
Open automatic (7)
Open automatic (7)
-
-
Open semi-automatic (8)
Open semi-automatic (8)
-
-
Pharmacy open (9)
Pharmacy open (9)
-
-
Key (10)
Key (10)
-
-
Partial Open (11)
Partial Open (11)
-
-
Closing safety (20)
Closing safety (20)
-
-
Opening safety (21)
Opening safety (21)
-
-
Emergency Open (30)
Emergency Open (30)
-
-
Emergency Open with memory (31)
Emergency Open with memory (31)
-
-
Emergency Stop (32)
Emergency Stop (32)
-
-
Emergency Stop with memory (33)
Emergency Stop with memory (33)
-
-
Emergency closing (34)
Emergency closing (34)
-
-
Emergency closing with memory (35)
Emergency closing with memory (35)
-
-
Modefun Open (40)
Modefun Open (40)
-
-
Modefun Exit only (41)
Modefun Exit only (41)
-
-
Modefun Entry only (42)
Modefun Entry only (42)
-
-
Modefun Night (43)
Modefun Night (43)
-
-
Modefun Manual (44)
Modefun Manual (44)
-
-
Modefun Partial (45)
Modefun Partial (45)
-
-
Modefun Interlock (46)
Modefun Interlock (46)
-
-
Timer (60)
Timer (60)
-
-
Reset (61)
Reset (61)
Default CF1 CF2 CF2 CF4 CF5
I1 1 1 1 1 --
I2 4 4 4 4 --
I3 10 10 10 10 --
I4 7 7 7 7 --
If the input has not been disabled, select the type of contact:
- Normally open (NO)
- Normally closed (NC)
Default CF1 CF2 CF2 CF4 CF5
Contact Normally closed (NC) --
3. If an input with CLOSURE SAFETY function has been selected, set
the TEST:
- Enabled
- Disabled
Default CF1 CF2 CF2 CF4 CF5
TEST Disabled --
4. Repeat the procedure for the other inputs.
1
LANGUAGE
MENU 2 PROGRAMMING
The menu is only accessible if the INSTALLER password has been entered.
If a different password has been inserted, it is indicated: MENU RESERVED
FOR INSTALLERS.
The list is:
- 1 DOOR TYPE
- 2 INPUTS / OUTPUTS
- 3 MOTION
- 4 TIMING
- 5 ENERGY SAVING
- 6 BATTERY KIT
- 7 MOTOR BLOCK KIT
- 8 INSTALLATION
- 9 SUNDRIES
- 10 LOG
DOOR TYPE
OK
OK
DOOR TYPE
2
PROGRAMMING
1. Select the type of door:
- NO
- A1000
- A1400
- RKE1400
- SF1400
Default CF1 CF2 CF2 CF4 CF5
DOOR TYPE NO NO NO NO --
If SF1400 is selected, two other menus are displayed:
2. NUMBER OF LEAVES select :
• 1 LEAF
• 2 LEAVES
3. PASSAGE OPENING with 1 LEAF selected:
• >= 75CM
• <=65CM
• >65CM
and <75cm
and <75cm
4. PASSAGE OPENING with 2 LEAVES selected:
• >= 150CM
• <=130CM
• >130CM
and <150cm
and <150cm

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FAAC A1000 and is the answer not in the manual?

FAAC A1000 Specifications

General IconGeneral
BrandFAAC
ModelA1000
CategoryDoor Opening System
LanguageEnglish

Related product manuals