A1000 92 532210 04 - Rev.A
Translation of the original instructions
ENGLISH
2 Partial opening
Defines the opening percentage in PARTIAL OPENING mode. The
default and interval of settings is:
- PARTIAL OPENING 20-100
3 Board Display
Enables/disables programming from the board. The options with
relevant default are as follows:
- Not blo
cked
- Blocked
4 Safety Opening Function
Defines the safety in opening function
- STOP
- LOW ENERGY (Slow speed movement)
5 Intrusion
Defines door behaviour in case of attempt to open manually. The
options
with relative defaults are as follows:
- DISABLED does not actuate the motor
- KEEP CLOSED actuates the closing motor
- PULL & GO actuates the opening motor
(NOT active with battery operation)
6 Partial Chemist’s Shop
It defines the opening percentage with the pharmacy control (only
active in NIGHT-TIME Mode). The default and interval of settings is:
- PARTIAL PHARMACY 20 % (1-95)
7 SDK EVO key
Defines the operation of the key switch connected to the SDK EVO
(OPTIONAL accessory):
- BLOCK:
The SDK EVO operates normally with the NO (Normally Open)
key switch. A password is required.
With the key switch NC (Normally Closed) the SDK EVO is locked.
- WITHOUT USER PSW:
With the key switch NO (Normally Open), the SDK EVO works
without having to enter a password.
With the key switch NC (Normally Closed), the SDK EVO works
normally. A password is required.
8 Consecutive obstacles
Defines the number of consecutive obstacles after which the door
is blocked in error. Choose and modify the parameter:
- CLOSING from no to 10
- OPENING from no to 10
No stands for infinity
9 Test Error
Enables/disables movement at slower speed in the event of TEST
ERROR on safety devices.
- ENABLED
- DISABLED
10 Display backlighting
Enables the backlighting of the display.
- ALWAYS
backlighting is always enabled)
- DISABLED
(backlighting is disabled after 30sec of SDKEVO key inactivity).
With battery operation it is always disabled.
11 ELASTIC KIT
- ENABLED
- DISABLED
Default CF1 CF2 CF2 CF4 CF5
Default Configuration NO -----
Partial opening 50% ---- ----
Board Display Not locked ----
Opening Safety Function LOW ENERGY ----
Intrusion Dis. Dis. Dis. Dis. ----
Partial Pharmacy 20% ----
SDK EVO key Lock ----
Consecutive obstacles 0 ----
Test Error Disabled -----
Display backlighting ALWAYS ------
ELASTIC KIT Disabled ------
■
10 LOG
OK
OK
LOG
2
PROGRAMMING
MENU NOT AVAILABLE
MENU 3 ERRORS
OK
OK
OK
OK
01 BOARD FAULT
3
ERRORS
02.....................39
99 Data deletion in
progress
The display shows current errors:
- 1 Board failure
- 4 VACC fault
- 5 Microcontroller error
- 6 VMOT fault
- 7 Motor MOT1 failure
- 9 VMAIN low
- 10 Battery discharged
- 11 S1 test failed
- 12 S2 test failed
- 15 Data in setup memory missing or corrupted
- 16 Encoder failure
- 18 FW not compatible
- 19 High mechanical friction
- 20 Test of inputs I1-I4 configured as safeties failed
- 22 Corrupted data
- 23 VMAIN high
- 24 Consecutive obstacles when closing
- 26 Motor block failure
- 27 Motor rotation error
- 29 AUX board fault
- 31 Consecutive obstacles during opening
- 32 Motor time out
- 33 Battery failure
- 38 Configuration error
- 39 Data in Setup memory missing or corrupted
- 99 Data deletion in progress