A1000 74 532210 04 - Rev.A
Translation of the original instructions
ENGLISH
17. INTERCOM CANBUS
PROGRAMMING ONLY WITH SDKEVO
■ Description
The E1SL board is capable of communicating with other E1SL units
via an Intercom network connection. This enables the following
functions to be used (Programming/Intercom/Function menu):
- INTERMODE: a master door from which to set the operating
mode for all the others that are connected to the network.
- INTERLOCK: two single doors, where the opening of one is sub-
ject to the closing of the other and vice versa
!
Every network-connected E1SL should be programmed for the same
Intercom mode.
■ Connection
The units in the network are connected via 3 cascade connected-wires
between the J18 connectors of the E1SL boards 71
The sequence in which the units are wired is unimportant, but it is es-
sential that a CASCADE connection is used.
■ Addressing
A unique Node ID (Programming/Intercom/MasterSlave_no menu)
must be assigned to each E1SL in the network as indicated below.
!
Do not assign the same Node ID to more than one unit in the network.
■ Registration
After having wired up and assigned an address to each unit, reg-
istration must be carried out (Programming/Intercom/Intercom/
Node registration) only on the Master E1SL that has been assigned
Node ID=1.
J18 J18
G CH CL G
G CH CL G
J18
G CH CL G
71