11 BASIC programming fw version 3.0 or later
BASIC Function CF1 CF2 CF3 CF4 CF5
CF
CF
Door type
no
no =no selection
1
1 = A1000
2
2 = A1400
3
3 = RKE 1400
4
4 = SF1400
5
5 =Rototranslating (not available)
The default values are reloaded if the parameter is modified.
no
no
no
no
no
no
no
no
-
-
dF
dF
DEFAULT configuration
The standard configuration is selected:
no
no = no Standard configuration in use
Y
Y = standard configuration in use
Y
Y
Y
Y
Y
Y
Y
Y
-
-
Ln
Ln
SELECT NUMBER OF LEAVES (displayed only for CF=4)
1
1 = 1 leaf
2
2 = 2 leaves
If the parameter is modified, SETUP must be performed.
-
-
-
-
-
-
4
4
-
-
Lt
Lt
SELECT PASSAGE OPENING (displayed only for CF=4)
1
1 = Narrow passage opening with 1 leaf <=65cm / with 2 leaves <=130cm
2
2 = Average passage opening with 1 leaf >65cm <75cm / with 2 leaves >130cm< 150cm
3
3 = Wide passage opening with 1 leaf >=75cm / with 2 leaves >= 150cm
-
-
-
-
-
-
4
4
-
-
rM
rM
The direction of rotation of the motor is selected:
1
1 = STANDARD rotation (*with belt fittings as per the configuration)
-1
-1 = NON-STANDARD rotation (*with belt fittings DIFFERENT to the configuration)
The choice becomes effective immediately. If the parameter is modified after SETUP has been
performed, error 38 is generated.
1
1
1
1
1
1
1
1
-
-
PO
PO
PARTIAL OPENING (not available for CF=4)
Set the opening percentage in Partial operating mode
no
no= 100% opening
Adjustable from 20% to 95% (MAX) of complete opening
Step = 5%
50
50
50
50
50
50
-
-
-
-
PA
PA
PAUSE TIME
This allows you to adjust the pause time of the fully open door.
Adjustable from
0
0 to
30
30 s.
Step = 1 s
2
2
2
2
2
2
2
2
-
-
The pause time is only active in automatic operation mode.
ES
ES
Energy Saving
no
no = not enabled
Y
Y = enabled
no
no
no
no
no
no
no
no
-
-
Pn
Pn
NIGHT PAUSE TIME
In night-time mode, if opening is done with the Key command, the door remains open for the time set with this
function.
Adjustable from
0
0 s to
4
4 minutes (MAX).
from
0
0 to
58
58 s, step = 2 s; time displayed in seconds.
from
58
58 to
4.0
4.0 minutes, step = 10 s; time displayed in minutes and tens of seconds: e.g.
1.2
1.2 = 1 minute and
20 seconds.
10
10
10
10
10
10
10
10
-
-
CS
CS
CLOSING SPEED
Adjustable from
1
1 (minimum) to
10
10 (MAX).
5
5
5
5
5
5
5
5
-
-