12 ADVANCED programming fw version 3.0 or later
ADVANCED Function CF1 CF2 CF3 CF4 CF5
P1
INPUT S1 CONFIGURATION
Allows parameter
P1 to be set.
See options as in
C1
20
20
20
20
-
1F
INPUT S1 TEST
parameter displayed only if
P1 =
20 or
21
Y = test enabled
no = test not enabled
Y
Y
Y
Y
-
P2
INPUT S2 CONFIGURATION
Allows parameter
P2 to be set.
See options as in
C1
20
20
20
20
-
2F
INPUT S2 TEST
parameter displayed only if
P2 =
20 or
21
Y = test enabled
no = test not enabled
Y
Y
Y
Y
-
Ot
OPERATION OF SAFETIES ON OPENING
1 = STOP (stops movement during opening)
2 = LOW ENERGY (motion slowed down)
2
2
2
2
-
bP
BUTTON PHOTOCELLS (OPTIONAL)
no = no photocell
1 = 1 pair of photocells
2 = 2 pairs of photocells
The test is NOT carried out on the button photocells.
no
no
no
no
-
E1
INPUT E1 CONFIGURATION
Allows parameter
E1 to be set.
See options as in
C1
no
no
no
no
-
1F
INPUT E1 TEST
parameter displayed only if
E1 =
20 or
21
Y = test enabled
no = test not enabled
no
no
no
no
-
E2
INPUT E2 CONFIGURATION
Allows parameter
E2 to be set.
See options as in
C1
no
no
no
no
-
2F
INPUT E2 TEST
parameter displayed only if
E2 =
20 or
21
Y = test enabled
no = test not enabled
no
no
no
no
-
bA
BATTERY KIT (NOT active in NIGHT-TIME mode)
Operation of the battery NOT in NIGHT-TIME mode with a mains power outage.
no = not enabled
1 = immediately perform OPENING motion
2 = immediately perform CLOSING movement
3 = with discharged battery last OPENING movement
4 = with discharged battery last CLOSING movement
no
no
no
no
-