A1000 57 532210 04 - Rev.A
Translation of the original instructions
ENGLISH
BASIC Function CF1 CF2 CF3 CF4 CF5
2F
SAFETY INPUT TEST I2
parameter displayed only if
C2 =
20 or
21
Y = test enabled
no = test not enabled
no
no
no
no
-
C3
INPUT I3 CONFIGURATION
Allows parameter
C3 to be set.
See options as in
C1
10
10
10
10
-
3F
SAFETY INPUT TEST I3
parameter displayed only if
C3 =
20 or
21
Y = test enabled
no = test not enabled
no
no
no
no
-
C4
INPUT I4 CONFIGURATION
Allows parameter
C4 to be set.
See options as in
C1
7
7
7
7
-
4F
SAFETY INPUT TEST I4
parameter displayed only if
C4 =
20 or
21
Y = test enabled
no = test not enabled
no
no
no
no
-
PF
PHARMACY OPEN (not available for CF=4)
Parameter displayed only if one of the inputs C1 ,C2, C3 ,C4, P1, P2, E1 or E2 is configured as Pharmacy OPEN.
Adjustable from 5% to 95% (MAX) of complete opening
Step = 5%
The input configured as Pharmacy functions in NIGHT-TIME mode; the other operating modes are
equivalent to an input configured as AUTOMATIC OPEN
20
20
20
20
-
St
EXIT PROGRAMMING
It lets you exit programming, and decide whether to save or not the modifications made.
Y = save (only if there are NO configuration errors)
no = do not save
Press F to confirm. After exit, the display shows automation status:
00 CLOSED
01 OPENING
02 OPEN
03 PAUSED
04 in NIGHT PAUSE
05 CLOSING
06 OPEN or STOPPED or CLOSED in EMERGENCY
07 in MANUAL mode
08 in NIGHT mode
10 System TEST in progress
11 STOPPED
12 safety devices TEST in progress
13 Door ERROR
(Press + and - simultaneously to
display the active ERROR)
LO-L2 PHASES LO, L1, L2 SETUP IN PROGRESS
. in SLEEP mode (point flashing)
Y
Y
Y
Y
-