A1000 56 532210 04 - Rev.A
Translation of the original instructions
ENGLISH
BASIC Function CF1 CF2 CF3 CF4 CF5
OS
OS
OPENING SPEED
Adjustable from
1
1 (minimum) to
10
10 (MAX).
10
10
8
8
8
8
5
5
-
-
CF
CF
CLOSING FORCE
Adjustable from
1
1 (minimum) to
10
10 (MAX).
5
5
5
5
5
5
5
5
-
-
OF
OF
OPENING FORCE
Adjustable from
1
1 (minimum) to
10
10 (MAX).
8
8
8
8
8
8
8
8
-
-
tF
tF
FORCE TIME on OBSTACLE for CF and OF
Adjustable from
0.1
0.1 to
3.0
3.0 sec. in 0.1 second steps.
1.0
1.0
1.0
1.0
2.0
2.0
1.0
1.0
-
-
dr
dr
ACCELERATION RAMP in OP and CL
Adjustable from
1
1 (minimum) to
10
10 (MAX).
6
6
6
6
6
6
4
4
-
-
Ar
Ar
ACCELERATION RAMP in OP and CL
Adjustable from
1
1 (minimum) to
10
10 (MAX).
8
8
8
8
5
5
8
8
-
-
C1
C1
INPUT I1 CONFIGURATION
NO input ( Programmable via SDK EVO
other selections and as NC contact)
no
no = input not enabled
1
1 = EXTERNAL OPEN
4
4 = INTERNAL OPEN
7
7 = Automatic OPEN
8
8 = Semi-automatic OPEN
9
9 = Pharmacy (not available for CF=4)
10
10 = KEY
11
11= partial OPEN (not available for CF=4)
20
20 = Closing Safety (NC)
21
21 = Opening Safety (NC)
30
30 = EMERGENCY OPENING (NC)
31
31 = EMERGENCY OPENING with MEMORY (NC)
32
32 = EMERGENCY STOP (NC)
33
33 = EMERGENCY STOP with MEMORY (NC)
34
34 = EMERGENCY CLOSING (NC)
35
35 = EMERGENCY CLOSING with MEMORY (NC)
40
40 = ALWAYS OPEN operating mode
41
41= EXIT ONLY operating mode
42
42= ENTRY ONLY operating mode
43
43= NIGHT-TIME operating mode
44
44= MANUAL operating mod
45
45= PARTIAL operating mode (not available for CF=4)
46
46=Interlock operating mode( *)
60
60=Timer
61
61=Reset
( *) the input becomes active ONLY if the
Interlock function has been programmed via the Intercom with SDK EVO.
Note : For specific functions of the inputs see ยง 14.2
1
1
1
1
1
1
1
1
-
-
1F
1F
SAFETY INPUT TEST I1
parameter displayed only if
C1
C1 =
20
20 or
21
21
Y
Y = test enabled
no
no = test not enabled
no
no
no
no
no
no
no
no
-
-
C2
C2
INPUT I2 CONFIGURATION
Allows parameter
C2
C2 to be set.
See options as in
C1
C1
4
4
4
4
4
4
4
4
-
-

Table of Contents