Drives
DRIVES
Single-drives
3.
Ref.2003
· 107 ·
QC-PDS
HARDWARE
X6 connector. IN|OUT.
Digital SERCOS-II interface
Connector that consists of a SERCOS-II signal receiver and emitter (IN,
OUT) and may be used to connect the QC-PDS system with the CNC · NO
QUERCUS · that controls the axes. The connection is made through fiber
optic lines and it has a ring structure.
It has a rotary switch for the node selection that identifies each of the
modules (both drives and regenerative power supplies) within the
SERCOS-II ring.
Installation
See sections, NODE IDENTIFICATION and INTERCONNECTION in 8.6.4 SERCOS-II
CONNECTIONS.
NOTE. Only available at the QC-DR-275-SS2 model.