Auxiliary modules
4.
AUXILIARY MODULES
Bus Protection Module
174
Ref.2003
· 170 ·
QC-PDS
HARDWARE
Function
X54. connector. Basic control signals
Male 4-pin connector located at the front of the unit and identified as X54.
Female aerial plug connector with a push-in connection supplied as an
accessory. The basic control signals are sent through it.
The following table shows the main data of the aerial connector and the wire
to be connected:
Pinout
Pin description
When the control circuit is supplied with +24 V DC (A18 connector) the
module runs an internal test. If it runs OK, it closes the status QC-BPM
OK status contact · pins 3 and 4 ·.
This contact stays closed while the supplied +24 V DC are maintained
and internally the module runs properly.
The consumption of these control signals is between 4.5 and 7 mA.
Installation
See section, 8.6.10 CONNECTIONS FOR BASIC CONTROL SIGNALS.
Connector data
Nr of poles 4
Gap (mm) 2.5
Maximum section permitted (mm²) 0.5
Connection data
Length to strip (mm) 8
Cross-section of solid conductor (mm²)
0.5
Cross-section of flexible conductor (mm²) 0.5
Cross-section of flexible conductor,
with a ferrule and without a plastic sleeve (mm²)
0.5
Length of socket (mm)
10
MANDATORY. ALWAYS make the connections using:
0.5 mm² cross-sectional conductors using a 10 mm sleeveless ferrule
.
Maximum length of the stripped end, 8 mm, or
0.34 mm² cross-sectional conductors using a 14.5 mm sleeved ferrule
.
Length of ferrule, 10 mm. Maximum length of the stripped end, 12 mm.
F. H4/23
X54 connector. Pinout.
T. H4/16
X54 connector. Pin description.
Pin Signal Description
1
QC-BPM
ERROR RESET
Error
RESET
input of the module.
24 V DC; 4.5 ÷ 7 mA.
2
GND
Reference 0 V DC
3
QC-BPM
OK
Contact indicating module status. It opens in case
of failure. Limit 1 A at 24 V.
4
QC-BPM
GND
1
2
3
4
ERROR RESET
QC-BPM OK
1
2
3
4

Table of Contents