Auxiliary modules
AUXILIARY MODULES
Bus Protection Module
4.
Ref.2003
· 171 ·
QC-PDS
HARDWARE
X56 connector.
External braking resistor connection
Male 6-pin connector located on top of the unit and identified as X56.
Female aerial plug connector with screw connection with tension sleeve
supplied as an accessory. Allows the connection of the external braking
resistor/s (also refer to Ballast resistor/s).
The following table shows the main data of the aerial connector and the
wire to be connected:
Pinout
The pinout is printed on the connector.
Pin description
Installation
See section, 8.5.7 CONNECTING THE EXTERNAL BRAKING RESISTORS FOR THE
QC-BPM-100.
D57, Status lights
FAULT. Top LED red. There is an error.
BALLAST. Middle LED amber. Crowbar ON.
READY. Bottom LED green. Unit ready.
Connector data
Nr of poles 6
Gap (mm) 7.62
Min./max. tightening torque (N·m) for S
4 mm² 0.5/0.6
Min./max. tightening torque (N·m) for S > 4 mm² 0.7/0.8
Flat screwdriver, size (mm) 0.6 x 3.5
Min./max. cross-section (mm²) 0.2/10
Maximum load current (A) 41
Connection data
Length to strip (mm) 10
F. H4/24
X56 connector. Pinout.
T. H4/17
X56 connector. Pin description.
Pin Signa Description
1
R1
R1 terminal connections for a ER+TH-18/1000 brake resistor
2
R1
3
R2
R2 terminal connections for a second ER+TH-18/1000 brake
resistor in parallel with R1.
4
R2
5
R3
R3 terminal connections for a third ER+TH-18/1000 brake
resistor in parallel with R1 and R2.
6
R3