Installation
INSTALLATION
Electrical connections
8.
Ref.2003
· 261 ·
QC-PDS
HARDWARE
WARNING. When running the cables for the power connection between
the QC-DR-
+
-FD2, size|1 dual-drive and two servomotors, connect the
U terminal of the X11A connector to the terminal corresponding to the U
phase of servomotor A. Perform the same procedure with terminals V-V
and W to W. In the same way, proceed with connector X11B for servomotor
B. Refer to the connectors X11A and X11B in chapter 3.
The multi-polar MPC-4xS cables have metallic shielding (shield) that, in
order to be compliant with the EC marking, must be connected to the GP-1
protective earth bar on the side of the drive. For the servomotor side, see
the MC-20/6 connector mounting in the FKM motor manual.