Chapter 4 Installation and Wiring
PAGE 4-40
2. Fastening Parameter Selection Signal and Start Timing
Select fastening parameter 2
OUT DATA 6
PARM SEL3
OUT DATA 10
PARM SEL4
Interlock the selection command and selection results after a dwell of 20ms.
START Signal
OFF
ON
START command issued if the (parameter select) above is
confirmed
PARMSELECT0
OFF
ON
PARMSELECT1
OFF
PARMSELECT2 OFF
PARMSELECT3 OFF
PARMSELECT4 OFF
BANK0
ON
BANK Selection Command
BANK1 ON
OFF
OUT DATA 3
PARM SEL0
OUT DATA 4
PARM SEL1
OUT DATA 5
PARM SEL2
Output fastening parameter (PARM
SELECT 0
4) selected by BANK setting
OFF
Contact is “Open” from PLC side
ON
Contact is “Closed” from PLC side
Fastening Parameter
(PARM SELECT 0
4)
Selection Command