EasyManua.ls Logo

FEC AFC3000 - Torque Inhibit Check; Breakaway Torque Check

FEC AFC3000
294 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 7 Fastening Instructions
PAGE 7-36
7-3-4 Torque Inhibit Check
The Torque Inhibit Check is used to ignore high torque spikes during initial starting of the motor or
fastening process. Under normal fastening operations Peak Torque will stop the fastening process (if
Standard Torque is reached). This may not be desirable for applications with high starting torque and
lower fastening torque. Applications such as self tapping screws, nylok nuts, crushed fasteners and
application with high starting inertia may require this function.
Torque Inhibit is set by the angle that is required to be “ignored” during the process. The Torque Inhibit
Limit is a torque limit used as protection in case the amount of torque monitored during the Torque Inhibit
Angle is too high. If this torque limit is hit during the Torque Inhibit process, then the spindle will stop and
an Abnormal is output.
111
Torque Inhibit Limit
205 Torque Inhibit Angle
103 Standard Torque
109 2
nd
Torque
105 1
ST
Torque
107 SNUG Torque
1
ST
Time
2
nd
Time
Angle (Time)
The set values stated below are ignored during the time between fastening start
and D-No.205 [Torque Inhibit Angle], when Torque Inhibit Check is enabled.
D-No.103
Standard Torque, D-No.104
Slow Down Start Torque
D-No.105
1
st
Torque, D-No.107
SNUG Torque, D-No.109
2
nd
Torque
D-No.112
1
st
Rate Start Torque, D-No.113 1
st
Rate End Torque
D-No.114
2
nd
Rate Start Torque, D-No.115 2
nd
Rate End Torque
D-No.116
3
rd
Rate Start Torque, D-No.117 3
rd
Rate End Torque
7-3-5 Break Away Torque Check
A Break Away Torque Check can be set to check the reverse torque on all reversing functions (whether a
reverse operation or part of an optional pre or post fastening operation). If the Reverse Torque Limit is
exceeded the reverse operation will stop and an Abnormal will be generated.
Angle (Time)
110 Reverse
Torque High Limit
Note: Reverse Torque judgment is done only by using Reverse 2 or Reverse 3 (from Sequence) or by the
fastening option “Reverse Before Fastening”. No Judgment will be made on Manual reverse
operations.
Torque
Torque

Table of Contents

Other manuals for FEC AFC3000