Chapter 2 Specifications
PAGE 2-2
2-1 Specification
2-1-1 AFC3000 System usage environment
Drive Power
Source
Voltage 3-phase 200 to 230V AC ±10%
Frequency
50
60Hz
Control Power Source* 24V DC ±10% 0.3A
Installation Environment
Install the Unit inside a dust proof housing (control panel).
When using this unit under conditions that do not conform to
this specification, a forced cooling device or heating device is
required.
Operation
Conditions
Ambient
Temperature
C to +45°C (32°F to 113°F)
Ambient
Humidity
90% Rh or lower (Avoid condensation)
Max. Motor
Case Temp.
70°C (158°F) (Outer Motor Case)
Storage
conditions
Ambient
Temperature
-5°C to +55°C (23°F to 131°F) (Avoid freezing)
Ambient
Humidity
90% Rh or lower (Avoid condensation)
Shipping
Conditions
Ambient
Temperature
-5°C to +55°C (23°F to 131°F) (Avoid freezing)
Ambient
Humidity
50% Rh or lower (Avoid condensation)
Package Tight seal
Do NOT use in an airtight environment.
The tool life will be shortend due to motor heat generation in an airtight
environment.
*NOTE: 24VDC power source should be separate source if controllers are to be powered through
separate power-on circuits or circuits containing high load devices. If 24VDC power drops below
18VDC (Approx.), the controller will re-boot.